ARGON FURNACE CONTROL

Argon Furnace System and Flow Panel

System Components
  • SSi's Model 9200
  • 15" industrial touch-screen operator interface
  • Allen Bradley SLC 5/04 PLC
  • SSi's 5-channel analog input modules
  • Dell inside door-mounted computer
  • Door mounted computer keyboard shelf



Operator Interface Screen
  • Screens to be viewed:
    • Furnaces 1, 2, & 3
    • Alarms
    • Control configurator
    • Alarm history
    • Trend charts
  • Within each of the furnaces you can view:
    • System overview
    • Flows for each furnace
    • DATA (set points and process variables for each zone within each furnace)
    • Motor switched (start/stop)
    • Alarms



Detail DATA from Furnace 3 (F3)
  • ZONE DATA (top, middle, and bottom)
    • Actual temperature
    • Temperature set point
    • Percent output
    • Manual control versus recipe or automatic
    • Trend charts
  • In addition, you can view the different load T/C's on each of the furnace cars

 
 