| |
THE SSi ANALYZER GROUP  SSi's DP2000 - Portable Dew Point Analyzer
Measured
Gases: Moisture Dew Point in Hydrocarbon Fuels |

 |
- Battery operated (truly portable)
- Simple operation
- Cell temperature readout
- Long like dielectric battery
- Built-in sample pump and filters
- LED digital readout
- No adjustments to make
| Specifications |
| Standard
Range: |
0 to 80oF (-17 to
27oC) |
| Display: |
Digital |
| Accuracy and
Repeatability: |
+/- 1 F |
| Operating
Temperature Range: |
0 to 120oF (-17 to
49oC) |
| Power: |
115/240 VAC 60Hz |
| Resolution: |
+/- 1 F |
| Zero and Span
Drift: |
+/- 1 F Maximum |
| Size and
Weight: |
11" H x 10" W x 7" L, 8 lbs |
| Output: |
4-20mA | |

Measures/Controls/Alarms: Moisture Dew Point
in Hydrocarbon Fuels |
 |
- Integral sample pump and filters
- LED digital readout
- No adjustments to make
| Specifications |
| Standard
Range: |
0 to 80oF (-17 to
27oC) |
| Display: |
Digital |
| Accuracy and
Repeatability: |
+/- 1 F |
| Operating
Temperature Range: |
0 to 120oF (-17 to
49oC) |
| Power: |
115/240 VAC 60Hz |
| Resolution: |
+/- 1 F |
| Zero and Span
Drift: |
+/- 1 F Maximum |
| Digital
Communications: |
RS485 (Modbus) |
| Output: |
4-20mA | |

- Dew point ranges from -148 to 20oF
(-100 to -7oC)
- Measures dew point in hydrocarbon fuels and plant
air systems
- Specifically suited for
hydrogen/nitrogen applications
- Integral filters
- LED digital readout
| Specifications |
| Standard
Range: |
-148 to 20oF (-100 to
-7oC) |
| Display: |
Digital |
| Accuracy and
Repeatability: |
+/- 1 F |
| Operating
Temperature Range: |
0 to 120oF (-17 to
49oC) |
| Power: |
115/240 VAC 60Hz |
| Resolution: |
+/- 1 F |
| Zero and Span
Drift: |
+/- 1 F Maximum |
| Digital
Communications: |
RS485 (Modbus) |
| Output: |
4-20mA | |
 |
| P/N 20263 Sample
Tube |
P/N 20264 NDIR Continuous Sample
Tube |
 |
 |
| A sight-glass has replaced
the plug |
| Simple
Dew |
Enclosure: 10"H x 8"W x
6"D Measures: Dew point in Hydrocarbon fuels |
 |
- Integral sample pump and filters
- Dew point range: 0 - 80oF
- Voltage output to PLC, DCS (Distributive Control
System)
|
 |
DPL4000 Portable Low Range
Dew Point Analyzer |
 |
- Measurement of very low dew points with high
accuracy
- Excellent long term stability
- Rapid response time with fast stabilizing dew
point reading
- Durable against condensation
- Includes hand-held instrument, sensor, sensor
housing, flow meter, quick connect fittings, logging software, and
durable carrying case
|
| Learn More
>> |
 |
|
 |