SINGLE-LOOP CONTROLLERS


The AC20 controller is designed to control both endothermic generators and atmosphere furnaces. To accomplish both, the AC20 can display and control on three units of measure: % Carbon, Dew Point or probe millivolts. In addition, Probe resistance, probe temperature, COF, H2F and probe recovery can be displayed.

• Simple to configure, simple to operate
• Designed specifically for atmosphere control
• Functions well on batch or continuous furnaces and endothermic generators
• 1/4 DIN, % Carbon, Dew Point, O2 Millivolts
• Internal timers for burn-out / probe maintenance
• On-board probe diagnostics
• Events: 8 IN - 10 OUT
• RS485, Modbus Communication protocol
• Ships pre-configured per your specifications
• Programmable when interfaced with SSi's eSPP


Cut-out Dimensions

20Q / 20PQ: 3.63W X 3.63H X 4.06D In
                   92W X 92H X 103D mm
7EK: 1.78W X 3.63H X 4.06 D In
        45W X 92H X 103D mm
7SL: 1.78W X 1.78H X 4.06D In
        45W X 45H X 103D mm


20 PQ Programmable Temperature Controller
20Q Temperature Controller - Non-programmable

 • 1/4 DIN, Universal inputs (P/N 31090)
 • Wide range of outputs (Relay, SSR, Triac, Servo)
 • Programmable (200 segments, up to 90 programs)
 • 11 logic inputs, 14 digital outputs, Clock / Calendar
 • Smart tuning function
 • Modbus® communications
 • 3 row, 4 digit LED, 2 bar-graph LED display
 • IP65, NEMA 4X,
 • 4 digital outputs,2 isolated mA outputs
 • Remote setpoint input
 • UL and cUL Approved, CE marked.

7EK - 1/8 DIN
 • 1/8 DIN, Universal inputs
 • 4 Relay outputs (P/N 31080)
 • 1 Current (4-20mA) and 3 relay outputs (P/N 31081)
 • 1 Slide-wire and 2 relay outputs (P/N 31082)
 • Smart tuning function
 • Modbus® communications
 • UL and cUL approved, CE marked.
7SL - 1/16 DIN  • 1/16 DIN, Universal inputs,
 • 1 Alarm (P/N 31302)
 • Modbus® communications optional
 • FM, UL, and cUL approved, CE marked.

*
All controllers have RS485 Communications
Specifications

Control Modes: PID or On/Off, motorized valve
Power: 100 – 240 VAC, 50/60Hz
Operating Ambient: 32°F to 130°F (0°C to 55°C)
                                20 - 85% RH non-condensing
Inputs: Universal thermocouple

Output Ratings

Relay:
2A, 264VAC resistive
Logic: 18VDC, 20mA
Triac: 1A, 264VAC resistive
DC
: Isolated 0-20mA at 12VDC

7205 EDINGTON DR. CINCINNATI, OH 45249 PHONE: 513.772.0060     FAX: 513.772.9466