SINGLE-LOOP ATMOSPHERE CONTROL
9120 Controller with Data Logging

PID Control for Dew Point / Carbon / O2 / Temperature / Millivolts
 

Enhanced Set Point Programmer and Digital Chart Recorder
  • 3.5" touch screen interface (other sizes available)
  • Digital data logging to flash card - built in paperless recording
  • DIN rail mount
  • 8 relay contacts
  • 24VDC (Power Supply Included)
  • Analog Outputs - PV Retransmission
  • Multiple PIDs
  • Overshoot supression logic
  • Auto tuning
  • PID switchpoints
  • Two (2) RS485, RS232, ETHERNET
  • 4-20mA current control output
  • Two (2) discreet inputs
  • 24 VDC power supply
  • Note: the 9120 does not run recipes
  Software Included  
  • Ts Manager - Data management for touch screen flashcard.       Remote data viewer, historical data backup, SuperDATA integration
  • Configurator - Remote setup and configuration of controller
  9120 Applications
Oxygen Probe mV Control
  • Single-loop control used for applications where mV reading from oxygen probe and temperature are used to control outputs
            Control loops:
 
  • mV
  • Temperature
  Nitriding
  Used for applications where H2 reading is used to calculate dissociated ammonia (DA).
              Outputs:
  • DA    0 - 100%
  • H2    0 - 100%
  Dual Loop
  Multi-loop control used for applications where universal input reading from analog input 1 and analog input 2 are used for setpoint control for both loops.
Single-Loop SSi Part No Control Outputs Alarms Inputs Digital In / Out Comms Data Logging
Model 9120 - % Carbon 13454 2 Relay (Gas &Air)
4-20mA Current
1 Alarm 2 Discreet
Sensor &TC
2 Digital In
1 Digital Out
(probe burnoff)
2 - RS485
1 - RS232
ETHERNET
With Advantech HMI
P/N 13316
Model 9120 - Dew Point 13454 2 Relay (Gas &Air)
4-20mA Current
1 Alarm 2 Discreet
Sensor &TC
2 Digital In
1 Digital Out
(probe burnoff)
2 - RS485
1 - RS232
ETHERNET
With Advantech HMI
P/N 13316
Model 9120 - Millivolts 13454 2 Relay (Gas &Air)
4-20mA Current
1 Alarm 2 Discreet
Sensor &TC
2 Digital In
1 Digital Out
(probe burnoff)
2 - RS485
1 - RS232
ETHERNET
With Advantech HMI
P/N 13316
Model 9120 - % Oxygen 13454 4-20mA Current 1 Alarm 2 Digital
Sensor &TC
2 4-20mA PV Retransmission
3 Digital Out
2 - RS485
1 - RS232
ETHERNET
With Advantech HMI
P/N 13316
Model 9120 - Temperature 13454 3 Digital Outs
Control and Alarms
4-20mA Current
1 Alarm 2 Universal T/C 2 Digital In
4-20mA
PV retransmit
2 - RS485
1 - RS232
ETHERNET
With Advantech HMI
P/N 13316

 
 
7205 EDINGTON DR. CINCINNATI, OH 45249 PHONE: 513.772.0060     FAX: 513.772.9466