Standard Atmosphere and Endothermic Generator Control Systems

SSi's Model 500
Single Furnace Reference Air / Probe Burnout System

  • Both reference air and burnout flow scopes
  • Internal reference air and burn off air sources
  • Designed to be mounted near the oxygen probe on the furnace
  • Picture shows the Model 500 for the Bazooka Probe / Endothermic Generator

Single Furnace Atmosphere Control System including Reference Air / Probe Burnout System
  • AC20 Atmosphere Controller
  • RS485 Modbus RTU communications port
  • Internal burn off air and recovery timers
  • Independent, external reference air and burn out flow scopes
  • Internal air sources
  • Designed to be mounted near the oxygen probe on the furnace
  • Model 1500 system on the left is for a Bazooka Probe / Endothermic Generator
  • Model 1500 system on the right is for typical furnace applications

Single Furnace Atmosphere and Temperature Control System including Reference Air / Probe Burnout System
  • AC20 Atmosphere Controller, 7EK Temperature Controller with 7SL hi-limit
  • RS485 Modbus RTU communications port
  • Internal burn off air and recovery timers
  • Independent, external reference air and burn out flow scopes
  • Internal air sources
  • Designed to be mounted near the oxygen probe on the furnace
  • Model 2500 system on the left is for a Bazooka Probe / Endothermic Generator
  • Model 2500 system on the right is for typical furnace applications
Description Part Number
HP2000 13019
SSi Gold Probe 11138 00
Model 1500 31051
Optional Pump 37177
HP2000 with 9000 Series Controller 13405
There are certain applications where an in-situ probe is impractical. For those situations, Super Systems recommends the HP2000 self-heated oxygen probe.
  • Multi-tube generators
  • Rotary retort furnaces
  • Muffle type furnaces
  • Shaker furnaces
  • Low-temperature applications
  • Sintering Applications
  • 3.5" color touch screen
  • Engineered for rotary, shaker, pit furnaces, and modular endothermic generator applications
  • Low temperature protective atmosphere applications
  • External sample applications when in situ probe is difficult to install
  • Paperless chart recorder
  • Requires sensor (P/N 1113800)
Atmosphere
Nitriding
Vacuum
12" x 23" Retrofit Plate - Atmosphere Batch Furnace
CaseMATETM or DualPROTM

Featuring:
Includes:
  • SSi's Model 9000 dual-loop controller (Ethernet and RS485 Modbus RTU communication ports)
  • Advantech operator interface with video recorder
  • Furnace hi-limit controller (7SL)
  • 24 VDC Isolation Relays
  • Power supply
  • Terminal blocks
  • Pre-wired and tested
  • Electrical drawings
19" x 24" Retrofit Plate - Atmosphere Batch Furnace
CaseMATETM or DualPROTM

Featuring:
Includes:
  • SSi's Model 9000 dual-loop controller (Ethernet and RS485 Modbus RTU communication ports)
  • Advantech operator interface with video recorder
  • Furnace hi-limit controller (7SL)
  • 24 VDC Isolation Relays
  • Power supply
  • Terminal blocks
  • Pre-wired and tested
  • Electrical drawings

 
 
7205 EDINGTON DR. CINCINNATI, OH 45249 PHONE: 513.772.0060     FAX: 513.772.9466