Standard Atmosphere and Endothermic Generator
Control Systems
 SSi's Model 500 Single Furnace Reference
Air / Probe Burnout System
 |
 |
- Both reference air and burnout flow scopes
- Internal reference air and burn off air sources
- Designed to be mounted near the oxygen probe on
the furnace
- Picture shows the Model 500 for the Bazooka
Probe / Endothermic Generator
|
 Single Furnace Atmosphere Control
System including Reference Air / Probe Burnout System |
 |
 |
 |
- AC20 Atmosphere Controller
- RS485 Modbus RTU communications port
- Internal burn off air and recovery timers
- Independent, external reference air and burn
out flow scopes
- Internal air sources
- Designed to be mounted near the oxygen probe on
the furnace
- Model 1500 system on the left
is for a Bazooka Probe / Endothermic Generator
- Model 1500 system on the right
is for typical furnace applications
|
 Single Furnace Atmosphere and
Temperature Control System including Reference Air / Probe Burnout
System |
 |
 |
 |
- AC20 Atmosphere Controller, 7EK Temperature
Controller with 7SL hi-limit
- RS485 Modbus RTU communications port
- Internal burn off air and recovery timers
- Independent, external reference air and burn
out flow scopes
- Internal air sources
- Designed to be mounted near the oxygen probe on
the furnace
- Model 2500 system on the left
is for a Bazooka Probe / Endothermic Generator
- Model 2500 system on the right
is for typical furnace applications
|
| Description |
Part Number |
| HP2000 |
13019 |
| SSi Gold Probe |
11138 00 |
| Model 1500 |
31051 |
| Optional Pump |
37177 |
| HP2000 with 9000 Series
Controller |
13405 | |
 |
| There are certain applications
where an in-situ probe is impractical. For those situations, Super
Systems recommends the HP2000 self-heated oxygen
probe. |
 |
- Multi-tube generators
- Rotary retort furnaces
- Muffle type furnaces
- Shaker furnaces
- Low-temperature applications
- Sintering Applications
|
 |
 |
- 3.5" color touch screen
- Engineered for rotary, shaker,
pit furnaces, and modular endothermic generator
applications
- Low temperature protective
atmosphere applications
- External sample applications when in
situ probe is difficult to install
- Paperless chart recorder
- Requires sensor (P/N 1113800)
|
 |
 |
Atmosphere Nitriding Vacuum |
12" x 23" Retrofit Plate
- Atmosphere Batch Furnace CaseMATETM or DualPROTM
Featuring: |
 |
 |
Includes: |
- SSi's Model 9000 dual-loop controller (Ethernet
and RS485 Modbus RTU communication ports)
- Advantech operator interface with video
recorder
- Furnace hi-limit controller (7SL)
|
- 24 VDC Isolation Relays
- Power supply
- Terminal blocks
- Pre-wired and tested
- Electrical drawings
|
19" x 24" Retrofit Plate
- Atmosphere Batch Furnace CaseMATETM or DualPROTM
Featuring: |
 |
 |
Includes: |
- SSi's Model 9000 dual-loop controller (Ethernet
and RS485 Modbus RTU communication ports)
- Advantech operator interface with video
recorder
- Furnace hi-limit controller (7SL)
|
- 24 VDC Isolation Relays
- Power supply
- Terminal blocks
- Pre-wired and tested
- Electrical drawings
|
 |
|
 |